Polycab 50 mm HMS FRLS uPVC Conduit Pipe – Heavy Mechanical Stress, 3 m Length, CPI0350001

50 mm outside diameter uPVC FRLS conduit, heavy mechanical stress class, IS 9537 Part 3: minimum inside diameter 43.2 mm, 3 m lengths, 15 per pack. Price on request.

Request price

Polycab 50 mm HMS FRLS uPVC Conduit Pipe (code CPI0350001) is a rigid uPVC FRLS (flame retardant, low smoke) conduit of the heavy mechanical stress class to IS 9537 (Part 3): 50 mm outside diameter (tolerance -0.5 mm), at least 43.2 mm inside diameter, supplied in 3 m lengths packed 15 to a standard pack. The 50 mm size is the largest size in the range - for mains, risers, feeder cables and many circuits in one run; the heavy class is meant for conduit cast into RCC slabs and floors, laid under floor screeds, or run where it can be knocked, stepped on or crushed.

Polycab India Limited is India's largest manufacturer of wires and cables, with 27 manufacturing facilities, 4,300+ authorised distributors, 2,00,000+ retailers and an export presence in 84 countries (polycab.com, October 2026). Polycab is ISO 9001:2015 certified and makes its conduits to IS 9537 (Part 3) and its conduit fittings to IS 3419, from what its catalogue calls "the highest grade of waterproof and fire-resistant polymers". Jai Enterprises supplies Polycab 50 mm HMS FRLS conduit from Bhilai and Raipur all over Chhattisgarh - Bhilai, Raipur, Durg, Korba, Bilaspur, Raigarh, Jagdalpur, Kanker, Ambikapur and every other district - and across India; price on request.

Is this the right one for you?

Check these five things before you order:

  • The wires fit the bore: at least 43.2 mm inside diameter - check the number and size of wires against the conduit-capacity table you work to.
  • The conduit is cast into an RCC slab, laid in a floor or exposed to knocks and loads - the heavy mechanical stress class is made for that.
  • Flame-retardant, low-smoke (FRLS) conduit is wanted or specified for the building.
  • In 50 mm Polycab lists couplers and long slip bends.
  • If the size does not fit: for fewer or smaller wires, 40 mm.

At a glance

  • Price: on request - call +91 9340081159
  • Product: Polycab 50 mm HMS FRLS uPVC Conduit Pipe
  • Product code: CPI0350001
  • Outside diameter: 50 mm (tolerance -0.5 mm)
  • Minimum inside diameter: 43.2 mm
  • Mechanical stress class: Heavy Mechanical Stress (IS 9537 Part 3)
  • Fire performance: FRLS - flame retardant, low smoke
  • Length: 3 m
  • Standard pack: 15 x 3 m (45 m)
  • Colours: black, ivory, grey and red in the Polycab colour chart (availability by size and series on enquiry)
  • Standard: IS 9537 (Part 3)

Specifications

  • Nominal size: 50 mm (outside diameter)
  • Tolerance on outside diameter: -0.5 mm
  • Minimum inside diameter: 43.2 mm (heavy class, IS 9537 Part 3 value printed in the Polycab catalogue)
  • Minimum inside diameter of the three classes at 50 mm: light 45.1 mm; medium 44.3 mm; heavy 43.2 mm
  • Length: 3 m per length
  • Standard pack: 15 x 3 m (45 m)
  • Product code: CPI0350001
  • Material: rigid uPVC, FRLS compound
  • Standard: IS 9537 (Part 3); fittings to IS 3419
  • Colours: black, ivory, grey and red in the Polycab colour chart (availability by size and series on enquiry)

Why choose Polycab HMS FRLS uPVC Conduit Pipe

  • Flame retardant, low smoke (FRLS) compound - resists the spread of flame and gives off less smoke, for safer wiring in homes and public buildings
  • Heavy Mechanical Stress class to IS 9537 (Part 3) - the thickest wall and smallest bore of the three classes, for conduit cast into RCC slabs and floors, laid under floor screeds, or run where it can be knocked, stepped on or crushed
  • Waterproof, fire-resistant polymer - the catalogue describes Polycab uPVC conduits as made "only from the highest grade of waterproof and fire-resistant polymers"
  • Five sizes, 20 to 50 mm outside diameter - one series for lighting, power, sub-mains and risers
  • 3 m lengths in standard packs - 75 lengths of 20 mm down to 15 lengths of 50 mm per pack, easy to count and order
  • Matching Polycab fittings to IS 3419 - circular and deep boxes, fan boxes, bends, tees, elbows, couplers, reducers and saddles

Using 50 mm conduit

Wires per conduit: a 50 mm conduit of the heavy class has at least 43.2 mm of clear bore. Work out how many wires it can take from the conduit-capacity table you follow (for example the one in IS 732) or the consultant's drawings, and step up a size for long runs with several bends.

Joining and bending: join lengths with a Polycab 50 mm coupler (PVC solvent cement makes the joint permanent in concealed work); use Polycab long slip bends for 50 mm, or a bending spring of the right size.

Fixing: fix surface runs with saddles at regular spacing; in slabs, tie the conduit to the reinforcement and seal open ends before the concrete is poured; leave a draw wire in long runs.

Where it is used

  • The largest size in the range - for mains, risers, feeder cables and many circuits in one run
  • Conduit cast into RCC roof and floor slabs
  • Floor runs under screeds and tiles
  • Industrial buildings, workshops and plant rooms

Other sizes of Polycab HMS FRLS uPVC Conduit Pipe

The Polycab HMS FRLS uPVC Conduit Pipe overview page compares all 5 side by side.

Related products

Frequently asked questions

What is the inside diameter of Polycab 50 mm HMS FRLS conduit?

At least 43.2 mm - the IS 9537 Part 3 minimum for the heavy class at 50 mm outside diameter (tolerance -0.5 mm), as printed in the Polycab catalogue. At 50 mm the three classes have a minimum bore of 45.1 mm (light), 44.3 mm (medium) and 43.2 mm (heavy).

How many lengths are in a pack of Polycab 50 mm HMS FRLS conduit?

15 lengths of 3 m - 45 m per standard pack. Tell us the number of lengths or packs you need.

What is the product code of Polycab 50 mm HMS FRLS conduit?

CPI0350001. Quote it on your purchase order or tender so the right series, class and size are supplied.

When is 50 mm conduit needed?

For mains and feeder cables, risers and runs that carry many circuits - it is the largest size in the Polycab range. Polycab lists couplers and long slip bends in 50 mm.

LMS, MMS or HMS - which class should I choose?

Light (LMS) for surface runs and above false ceilings, medium (MMS) for conduit concealed in walls and ceilings, heavy (HMS) for slabs, floors and places where the conduit can be crushed or knocked. At 50 mm the minimum bore is 45.1 mm (light), 44.3 mm (medium) and 43.2 mm (heavy).

Where can I buy Polycab 50 mm HMS FRLS conduit in Chhattisgarh?

From Jai Enterprises, Bhilai and Raipur, which supplies Polycab conduits and fittings across Chhattisgarh - Korba, Bilaspur, Raigarh, Jagdalpur, Kanker, Ambikapur and every other district - and across India. Call +91 9340081159 with the size, quantity and delivery location and we will confirm the price, availability and lead time.

How to order

Supplied by Jai Enterprises, Bhilai and Raipur, to every district of Chhattisgarh and across India. To request a price for Polycab 50 mm HMS FRLS conduit (CPI0350001), call +91 9340081159 or send an enquiry from this page with the size, the quantity (lengths or packs) and the delivery location, and we will confirm the price, stock and lead time.

Applications

  • Industrial plants
  • Utilities
  • Infrastructure projects
  • Commercial facilities

Availability: Enquiry-based — contact us for stock and lead time.

Share this product

1 of n