Triple pole MCB, C curve, 10 kA, 0.5 A to 125 A. MRP Rs 1,410 - 2,179 per piece; 80 to 125 A: price on request.

MRP Rs 1,410 - 2,179 per piece (0.5 to 63 A)

The Polycab 10kA C-Curve TP MCB is a triple pole (3 pole) miniature circuit breaker with a C tripping curve and 10 kA breaking capacity. Its 14 ratings from 0.5 to 63 A - 0.5, 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40 and 63 A - are made to IS/IEC 60898-1 for 240/415 V AC, 50 Hz, at MRP Rs 1,410 to Rs 2,179 per piece (polycab.com, October 2026). Polycab's switchgear technical catalogue (October 2024 edition) also lists 80, 100 and 125 A versions - C curve, 10 kA, made to IS/IEC 60947-2 - at a price on request.

Polycab India Limited is India's largest manufacturer of wires and cables, with 27 manufacturing facilities, 4,300+ authorised distributors, 2,00,000+ retailers and an export presence in 84 countries (polycab.com, October 2026). Its switchgear range covers MCBs, RCCBs, RCBOs, isolators, changeover switches, ACCLs and distribution boards. Jai Enterprises supplies Polycab MCBs from Bhilai and Raipur all over Chhattisgarh - Bhilai, Raipur, Durg, Korba, Bilaspur, Raigarh, Jagdalpur, Kanker, Ambikapur and every other district - and across India.

Is this the right one for you?

Check these five things before you order:

  • The load is three-phase without neutral, for example a three-phase motor (triple pole).
  • Your load suits a C curve: three-phase pumps, compressors, motors and mixed three-phase loads.
  • The prospective short-circuit current where the MCB is fitted does not exceed 10 kA.
  • The rating you need is 0.5, 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40 or 63 A, or 80, 100 or 125 A (price on request) - the rating must suit the cable it protects.
  • For 80 to 125 A: the board has room for the wider breaker - 80.4 mm against 52.5 mm for the smaller ratings - and a busbar to suit; the pin or fork busbar of the smaller MCBs does not fit. Your cables suit the rating and fit the terminals (up to 50 sq mm).

At a glance

  • MRP: Rs 1,410 - 2,179 per piece (polycab.com, October 2026, inclusive of taxes); 80 to 125 A: price on request
  • Product: Polycab 10kA C-Curve TP MCB
  • Type: triple pole MCB, C curve, 10 kA
  • Poles: TP - triple pole (3 pole)
  • Tripping curve: C
  • Breaking capacity: 10 kA
  • Ratings: 0.5, 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40 and 63 A; 80, 100 and 125 A (price on request)
  • Item codes: GMM203P001 to GMM203P008 and GMM203P012 to GMM203P017; GMM203P080, GMM203P0100 and GMM203P0125 (80 to 125 A)
  • Standard: IS/IEC 60898-1 (0.5 to 63 A); IS/IEC 60947-2 (80 to 125 A)
  • Rated voltage: 240/415 V AC, 50 Hz (0.5 to 63 A); 415 V AC (80 to 125 A)
  • Width: 52.5 mm (0.5 to 63 A); 80.4 mm (80 to 125 A)
  • Warranty: 7 years for the 0.5 to 63 A ratings (as listed by Polycab); ask us for 80 to 125 A

Ratings, item codes and MRP

  • 0.5 A: item code GMM203P012 - MRP Rs 1,690
  • 1 A: item code GMM203P013 - MRP Rs 1,690
  • 2 A: item code GMM203P014 - MRP Rs 1,690
  • 3 A: item code GMM203P015 - MRP Rs 1,690
  • 4 A: item code GMM203P016 - MRP Rs 1,690
  • 5 A: item code GMM203P017 - MRP Rs 1,690
  • 6 A: item code GMM203P001 - MRP Rs 1,410
  • 10 A: item code GMM203P002 - MRP Rs 1,410
  • 16 A: item code GMM203P003 - MRP Rs 1,410
  • 20 A: item code GMM203P004 - MRP Rs 1,410
  • 25 A: item code GMM203P005 - MRP Rs 1,410
  • 32 A: item code GMM203P006 - MRP Rs 1,410
  • 40 A: item code GMM203P007 - MRP Rs 1,970
  • 63 A: item code GMM203P008 - MRP Rs 2,179
  • 80 A: item code GMM203P080 - price on request
  • 100 A: item code GMM203P0100 - price on request
  • 125 A: item code GMM203P0125 - price on request
  • 80 to 125 A ratings: C curve, made to IS/IEC 60947-2, rated 415 V AC, rated short-circuit capacity 10 kA (Icn, as Polycab lists it) and Ics 7.5 kA, terminals up to 50 sq mm (tightening torque 3.5 Nm), 80.4 mm wide and 80.5 mm high; listed in Polycab's switchgear technical catalogue (October 2024 edition), pp 32 and 33, at a price on request
  • MRP basis: MRPs as listed on polycab.com, October 2026, inclusive of taxes; the selling price is confirmed on enquiry
  • 0.5 to 5 A ratings: for control circuits, indicator and instrument supplies and other small loads

Why choose the Polycab 10kA C-Curve TP MCB

  • Easy removal from the DIN rail
  • Positive contact position indication - the handle shows whether the contacts are really open
  • Finger-proof IP20 terminals
  • Air-flow channels to keep the breaker cool
  • Label holder to mark the circuit
  • 7-year warranty listed by Polycab for the 0.5 to 63 A ratings
  • High-quality contact tips
  • Large terminals that take copper or aluminium conductors
  • Bi-connect terminals on both sides - busbar or cable (0.5 to 63 A)
  • Line-load reversibility - it can be fed from the top or the bottom
  • 10 kA breaking capacity, and energy limiting class 3 as Polycab's catalogue lists for the range
  • 80, 100 and 125 A versions - C curve, 10 kA, made to IS/IEC 60947-2 - for heavier loads (price on request); the other features in this list are those Polycab gives for the 0.5 to 63 A ratings
  • Polycab item code for every rating and the MRP for 0.5 to 63 A, so the order matches the drawing - GMM203P001 to GMM203P008, GMM203P012 to GMM203P017, GMM203P080, GMM203P0100 and GMM203P0125

How to choose and fit it

Tripping curve. Under IS/IEC 60898-1, a B-curve MCB trips instantly at 3 to 5 times its rated current, a C-curve at 5 to 10 times and a D-curve at 10 to 20 times. This C-curve breaker trips instantly at 5 to 10 times its rating, which suits three-phase loads with a moderate switch-on surge - pumps, compressors, air-handling units, motors and the mixed loads of three-phase sub-boards; it is the most widely used curve. (The 80 to 125 A ratings are made to IS/IEC 60947-2, which does not define B, C and D curves; Polycab lists them as C curve.)

Poles. A triple pole MCB is used for a three-phase load without neutral, such as a three-phase motor or pump. In the 10 kA C-curve range Polycab lists SP, SPN, DP, TP, TPN and FP.

Breaking capacity. 10 kA is the largest short-circuit current the breaker can safely interrupt. Choose a breaking capacity at least equal to the prospective fault current where it is fitted - your electrician or consultant checks this at the board.

Rating. Choose a rating above the running current of the load and within the current-carrying capacity of the cable it protects; for motors, also check the starting current against the curve and the motor maker's recommendation.

80 to 125 A. Polycab's switchgear technical catalogue (October 2024 edition) lists these higher ratings for heavy-duty devices, commercial and industrial settings and solar systems. They are AC breakers (415 V AC), so in a solar system they go on the AC side - DC circuits need breakers rated for DC at the string's maximum open-circuit voltage. At about 27 mm per pole (80.4 mm against 52.5 mm for the 0.5 to 63 A ratings) they need more room, so check the space in the board, and that its busbar and the cables suit the rating. The catalogue gives no temperature derating or reverse-feed rating for them, so leave a margin in a hot panel and ask us before feeding one from its outgoing terminals, for example from an inverter. Polycab's RCCBs go up to 63 A, and an RCCB must be rated at least as high as the MCB that protects it, so do not fit one directly behind an 80, 100 or 125 A breaker - put the RCCBs on the outgoing circuits, each behind an MCB no larger than its rating. Price on request.

Mounting. It clips on a standard DIN rail inside a distribution board or MCB enclosure.

Where it is used

  • three-phase pumps, compressors, air-handling units and machines without neutral
  • three-phase sub-mains without neutral
  • homes, apartments, offices, shops, hospitals, schools and factories
  • three-phase 80 to 125 A feeders and heavy-duty loads in commercial and industrial buildings, and the AC side of three-phase solar inverters without a neutral connection - with a neutral, use the FP (price on request)

Other Polycab 10 kA MCBs

Related products

Frequently asked questions

What does "C curve" mean on an MCB?

It describes how quickly the breaker trips on a surge. Under IS/IEC 60898-1 a C-curve MCB trips instantly at 5 to 10 times its rated current, which suits three-phase pumps, compressors, motors and mixed three-phase loads. B trips at 3 to 5 times, C at 5 to 10 times and D at 10 to 20 times the rating.

Which pole type do I need?

SP protects one single-phase circuit; SPN switches the neutral together with the phase; DP switches and protects phase and neutral of a single-phase supply; TP is for three-phase loads without neutral; TPN switches the neutral together with the three phases; FP switches all four poles of a three-phase supply with neutral and is the usual incomer of a TPN distribution board. This page is the triple pole (TP) version; in the 10 kA C-curve range Polycab lists SP, SPN, DP, TP, TPN and FP.

Should I choose a 10 kA or a 6 kA MCB?

Choose a breaking capacity at least equal to the prospective short-circuit current at the board. 6 kA is common in homes; 10 kA is the safer choice for commercial buildings, boards close to the transformer and industrial supplies. Polycab makes the TP C-curve MCB in both.

Is there an 80, 100 or 125 A version?

Yes. Polycab's switchgear technical catalogue (October 2024 edition) lists the TP C-curve 10 kA MCB in 80 A (GMM203P080), 100 A (GMM203P0100) and 125 A (GMM203P0125), made to IS/IEC 60947-2 for 415 V AC with a 7.5 kA service breaking capacity (Ics), at a price on request. They are 80.4 mm wide, against 52.5 mm for the 0.5 to 63 A ratings. Call +91 9340081159 for the price and lead time. For a feeder or panel incomer that needs 10 kA in service (Ics) at 415 V AC, a shunt release, an auxiliary switch or a rotary handle on the panel door, see the Polycab TP MCCB.

Do I still need an RCCB with an MCB?

Yes, for protection against electric shock and earth-leakage fires. An MCB protects against overload and short circuit only; an RCCB (or an RCBO, which combines both) detects current leaking to earth.

What is the MRP of the Polycab 32 A 10kA C-curve TP MCB?

Rs 1,410 per piece, item code GMM203P006 - the MRP listed on polycab.com in October 2026, inclusive of taxes. Call +91 9340081159 for the selling price and stock.

Where can I buy the Polycab 10kA C-Curve TP MCB in Chhattisgarh?

From Jai Enterprises, Bhilai and Raipur, which supplies Polycab switchgear all over Chhattisgarh - Korba, Bilaspur, Raigarh, Jagdalpur, Kanker, Ambikapur and every other district - and across India. Call +91 9340081159 with the rating, quantity and delivery location and we will confirm the price, stock and lead time.

How to order

Supplied by Jai Enterprises, Bhilai and Raipur, to every district of Chhattisgarh and across India. Polycab lists the 0.5 to 63 A ratings of the 10kA C-Curve TP MCB at MRP Rs 1,410 - 2,179 per piece (polycab.com, October 2026, inclusive of taxes); the 80, 100 and 125 A versions are supplied at a price on request. Call +91 9340081159 or send an enquiry from this page with the rating, the quantity (pieces) and the delivery location, and we will confirm the selling price, stock and lead time.

Applications

  • Industrial plants
  • Utilities
  • Infrastructure projects
  • Commercial facilities

Availability: Enquiry-based — contact us for stock and lead time.

Share this product

1 of n