Product Range
Contact Us

Polycab Service Wire – Solid Aluminium, PVC Insulated and Sheathed Twin Flat Cable, IS 694:2010

Solid aluminium, PVC insulated and PVC sheathed twin flat cable for electricity service connections (catalogue standard: IS 694:2010). Price on request.

Request price

The Polycab Service Wire is a solid aluminium, PVC insulated and PVC sheathed twin flat cable for electricity service connections from the supply line to the meter. Polycab's catalogue lists it as conforming to IS 694:2010. It is supplied at a price on request: cable prices depend on the construction, the quantity and the raw-material prices on the day.

Polycab India Limited is India's largest manufacturer of wires and cables, with 27 manufacturing facilities, a network of 4,300+ dealers and distributors, 2,00,000+ retailers and an export presence in 84 countries (polycab.com, October 2026). Its cable range runs from house wires and 1.1 kV power and control cables to MV and EHV power cables, with instrumentation, solar, railway, marine, mining, fire-survival and other special cables. Jai Enterprises supplies Polycab cables from Bhilai and Raipur all over Chhattisgarh - Bhilai, Raipur, Durg, Korba, Bilaspur, Raigarh, Jagdalpur, Kanker, Ambikapur and every other district - and across India.

Is this the right one for you?

Check these four things before you order:

  • The cable is a single-phase service connection - from the pole or LT line to the meter.
  • You know the size your electricity utility specifies.
  • Your circuit is within IS 694's rating (up to 450/750 V) - a single-phase 230 V supply is.
  • The meter-side and pole-side connectors are suitable for aluminium, and outdoor runs will use the outdoor type.

At a glance

  • Price: on request - call +91 9340081159
  • Product: Polycab Service Wire
  • Type: service wire (service connection cable)
  • Conductor: solid aluminium
  • Construction: twin flat, PVC insulated, PVC sheathed
  • Standard: IS 694:2010, as listed in the catalogue (see the note)
  • Source: Polycab B2B all-products catalogue (2025), p 30

Construction and standards

  • Conductor: solid aluminium
  • Cores: two, laid flat
  • Insulation: PVC
  • Sheath: PVC, twin flat
  • IS 694: PVC insulated cables and cords up to and including 450/750 V
  • Note - Standard: IS 694:2010's flat-cable clause (clause 22, as amended in 2012) specifies stranded (class 2) or flexible (class 5) conductors, while the catalogue lists a solid aluminium conductor - we confirm the standard and its certification with Polycab before you order
  • Source: Polycab B2B all-products catalogue (2025), p 30

Why choose the Polycab Service Wire

  • Twin flat aluminium cable for single-phase service connections
  • PVC insulated and PVC sheathed
  • Solid aluminium conductors

How to choose and specify it

Size. Electricity utilities specify the service-wire size for the sanctioned load; send us the size or the load.

Aluminium terminations. This wire's conductors are solid in every size, so use lugs and connectors rated for solid aluminium conductors of that size. The HEX ranges below start at 16 sq mm and are made mainly for stranded compacted conductors, so ask us to confirm. Clean the conductor and apply a corrosion-inhibiting compound before connecting, then tighten the connection properly to avoid hot joints.

Outdoor and overhead runs. Ask for the IS 694 outdoor type (category 02, marked 'OU'); on spans, support the cable on a bearer (catenary) wire as the utility requires - the conductors should not carry the cable's weight.

Where it is used

  • Electricity service connections to homes and shops
  • Utility (DISCOM) new connections
  • Rural electrification connections

Other Polycab flexible cables and building wires

Related products

Frequently asked questions

What is the price of the Polycab Service Wire?

The Polycab Service Wire is supplied at a price on request, because cable prices depend on the construction, the quantity and the raw-material prices on the day. Call +91 9340081159 for a quotation.

What is a service wire?

The twin cable that connects a consumer's meter to the utility supply - here a solid aluminium, PVC insulated and sheathed twin flat cable.

Which standard does it follow?

Polycab's catalogue lists it as conforming to IS 694:2010 (PVC insulated cables up to 450/750 V). The flat-cable clause of IS 694 specifies stranded or flexible conductors, while this wire is solid aluminium, so we confirm the standard and its certification with Polycab before you order.

Which size do I need?

The size your electricity utility specifies for the sanctioned load.

Where can I buy the Polycab Service Wire in Chhattisgarh?

From Jai Enterprises, Bhilai and Raipur, which supplies Polycab cables to every district of Chhattisgarh and across India. Call +91 9340081159 for the price, stock and lead time.

How to order

Price on request: call +91 9340081159 or send an enquiry from this page with the size, whether it runs outdoors or overhead, the length and the delivery location, and we will confirm the price, availability and lead time. Ask for the Polycab datasheet for your exact construction before you order.

Applications

  • Industrial plants
  • Utilities
  • Infrastructure projects
  • Commercial facilities

Availability: Enquiry-based — contact us for stock and lead time.

Share this product

1 of n