Polycab Marine and Offshore Cable – Ship Wiring, 0.15/0.25 kV to 18/30 kV, IEC 60092, NEK 606

Bare or tinned copper ship and offshore cables, EPR, XLPE, silicone or HF XLPO insulated, 0.15/0.25 to 18/30 kV, unarmoured or braid armoured. Price on request.

Request price

The Polycab Marine and Offshore Cable range covers ship wiring and offshore cables from 0.15/0.25 kV to 18/30 kV, with bare or tinned copper conductors, EPR, XLPE, silicone or halogen-free XLPO insulation, unarmoured or metallic braid armoured, with PCP, CSP or halogen-free rubber sheaths. Polycab's catalogue lists it as conforming to IEC 60092-350, IEC 60092-353, IEC 60092-360, IEC 60092-376, NEK 606, BS 6883 and BS 7917. It is supplied at a price on request: cable prices depend on the construction, the quantity and the raw-material prices on the day.

Polycab India Limited is India's largest manufacturer of wires and cables, with 27 manufacturing facilities, a network of 4,300+ dealers and distributors, 2,00,000+ retailers and an export presence in 84 countries (polycab.com, October 2026). Its cable range runs from house wires and 1.1 kV power and control cables to MV and EHV power cables, with instrumentation, solar, railway, marine, mining, fire-survival and other special cables. Jai Enterprises supplies Polycab cables from Bhilai and Raipur all over Chhattisgarh - Bhilai, Raipur, Durg, Korba, Bilaspur, Raigarh, Jagdalpur, Kanker, Ambikapur and every other district - and across India.

Is this the right one for you?

Check these four things before you order:

  • The cable is for a ship, an offshore unit or a marine installation.
  • You know the circuit type: power, control or instrumentation, and the voltage grade.
  • You know whether the vessel needs cable approved by a classification society, such as the Indian Register of Shipping (IRS), DNV, ABS or Lloyd's Register.
  • You know whether halogen-free, fire-resistant or mud-resistant versions are needed.

At a glance

  • Price: on request - call +91 9340081159
  • Product: Polycab Marine and Offshore Cable
  • Type: marine, ship wiring and offshore cables
  • Conductor: annealed bare or tinned copper
  • Cores: single or multicore
  • Insulation: EPR, XLPE, silicone rubber or halogen-free XLPO
  • Voltage grade: 0.15/0.25 kV to 18/30 kV
  • Screen and armour: screened or unscreened; unarmoured or metallic braid armoured
  • Sheath: PCP, CSP or halogen-free rubber
  • Standards: IEC 60092-350, -353, -360 and -376, NEK 606, BS 6883, BS 7917
  • Source: Polycab B2B all-products catalogue (2025), p 22

Construction and standards

  • Conductor: annealed bare or tinned copper
  • Cores: single or multicore
  • Insulation: EPR, XLPE, silicone rubber or halogen-free XLPO
  • Screen: screened or unscreened
  • Armour: unarmoured or metallic braid
  • Outer sheath: PCP, CSP or halogen-free rubber
  • IEC 60092-350: ship and offshore power, control and instrumentation cables - general construction and tests, up to 18/30 (36) kV
  • IEC 60092-353: ship and offshore power cables for 1 kV and 3 kV
  • IEC 60092-360: insulating and sheathing materials for ship and offshore cables
  • IEC 60092-376: ship and offshore control and instrumentation cables, 150/250 V (300 V)
  • NEK 606: Norwegian offshore cable specification for halogen-free and mud-resistant cables
  • BS 6883: elastomer insulated cables for fixed wiring in ships and offshore units, up to 8.7/15 kV
  • BS 7917: elastomer insulated fire-resistant cables for ships and offshore units, up to 3.3 kV
  • Note - NEK 606: the Norwegian offshore cable specification is now published as NEK TS 606 (2025 edition)
  • Source: Polycab B2B all-products catalogue (2025), p 22

Why choose the Polycab Marine and Offshore Cable

  • From 0.15/0.25 kV control and instrumentation cables up to 18/30 kV power cables
  • Tinned copper conductors for salt-laden air
  • EPR, XLPE, silicone or halogen-free XLPO insulation
  • Unarmoured, or metallic braid armoured - the braid is flexible and easy to gland on board
  • Halogen-free and mud-resistant offshore options (NEK 606)
  • Custom designs to customer specifications

How to choose and specify it

Standard. IEC 60092-350 sets the general construction and tests for shipboard power, control and instrumentation cables up to 18/30 (36) kV; IEC 60092-353 covers 1 kV and 3 kV power cables and IEC 60092-376 the 150/250 V control and instrumentation cables. NEK 606 is the Norwegian offshore specification, and BS 6883 / BS 7917 are the British ship-wiring standards.

Class approval. Ships and offshore units usually need cables approved by the classification society. Tell us the class (for example IRS, DNV, ABS or Lloyd's Register) and we confirm the approval status for each type with Polycab.

Fire and mud. For accommodation and enclosed spaces, choose a halogen-free cable: PCP and CSP sheaths contain chlorine, so ask for a halogen-free (HF) rubber sheath over halogen-free insulation (the catalogue lists XLPO HF; we confirm HF versions of the other insulations). Choose fire-resistant types (BS 7917) for emergency circuits, and mud-resistant types where drilling fluids are present.

Medium voltage and armour. MV ship cables (6 kV and above) are normally specified to IEC 60092-354, which the catalogue does not list, or, up to 8.7/15 kV, to BS 6883 - tell us your specification and we confirm the MV construction with Polycab. Single-core cables on AC circuits need a non-magnetic (for example tinned copper) braid; tell us the circuit.

Glands. In hazardous areas offshore, use Ex-certified glands suited to the cable. Terminate and earth the braid as the yard, class or project rules require, in a gland that clamps the braid or with a separate earthing clamp.

Where it is used

  • Shipbuilding and ship repair - power, lighting and control wiring
  • Offshore platforms, rigs and FPSOs
  • Naval and coast guard vessels
  • Dredgers, tugs and barges
  • Port and harbour craft

Other Polycab marine, mining and special cables

Related products

Frequently asked questions

What is the price of the Polycab Marine and Offshore Cable?

The Polycab Marine and Offshore Cable is supplied at a price on request, because cable prices depend on the construction, the quantity and the raw-material prices on the day. Call +91 9340081159 for a quotation.

Which voltage grades are available?

From 0.15/0.25 kV to 18/30 kV, as the catalogue lists.

Is the cable class approved?

The catalogue does not list class approvals. Tell us the classification society your vessel needs, and we confirm the approval status for the cable type with Polycab before you order.

What is NEK 606?

The Norwegian specification for offshore cables, covering halogen-free and mud-resistant types.

Where can I buy the Polycab Marine and Offshore Cable in Chhattisgarh?

From Jai Enterprises, Bhilai and Raipur, which supplies Polycab cables to every district of Chhattisgarh and across India. Call +91 9340081159 for the price, stock and lead time.

How to order

Price on request: call +91 9340081159 or send an enquiry from this page with the circuit type, the voltage grade, the size and cores, the version needed (halogen-free, fire-resistant or mud-resistant), the armour (unarmoured or braid armoured), the standard, the class approval, the length and the delivery location, and we will confirm the price, availability and lead time. Ask for the Polycab datasheet for your exact construction before you order.

Applications

  • Industrial plants
  • Utilities
  • Infrastructure projects
  • Commercial facilities

Availability: Enquiry-based — contact us for stock and lead time.